   - 16.4. Storage battery
      16.4.1. Normal charging of the storage battery
      16.4.2. The accelerated charging of the storage battery
      16.4.3. Check of the storage battery
      16.4.4. Check of level of electrolit
      16.4.5. Check of density of electrolit
      16.4.6. Check of tension of the storage battery
      16.4.7. Check of tension of the storage battery under loading
      16.4.8. Check of the current consumed from the storage battery at switched-off ignition
      16.4.9. Power failure check on connections of plugs of the storage battery
   16.5. Starter
   16.6. Check at a provorachivaniye of a cranked shaft not the heated-up engine
   16.7. Check of an electric chain of the traction relay
   16.8. Check of the traction relay
   16.9. Check of brushes and shchetkoderzhatel
   16.10. Check of coils of a stator
   16.11. Rotor check
   16.12. Removal and starter installation
   16.13. Starter repair
   16.14. Multipurpose switch
   16.15. Sound signal
   16.16. The block of safety locks and the relay, established in car salon
   16.17. Check of the relay of the activator of the lock of a door
   16.18. Check of the switch of adjustment of provision of an external rear-view mirror
   16.19. Check of the activator of provision of an external rear-view mirror
   16.20. Check of the engine of a window regulator
   16.21. Check of a heater of back glass
   16.22. Repair of a current-carrying strip of a heater
   16.23. Engine of a screen wiper of a windscreen
   16.24. Stekloomyvateli
   16.25. Adjustment of light of headlights
   16.26. Adjustment of light of fog lights
   16.27. Safety cushions (SRS)
   16.28. Precautionary labels
   16.29. Safety cushion of the driver and spiral wire
   16.30. Safety cushion check
   16.31. Check of a spiral wire (spring)
   16.32. Safety cushion of the forward passenger
   + 16.33. Electric circuits


16.4.9. Power failure check on connections of plugs of the storage battery

GENERAL INFORMATION

Power failure check on connections of plugs of the storage battery will allow to define resistance size between a wire connected to the plug of the storage battery and the plug of the storage battery.

At performance of this check it is necessary to remember that power failure between two points of connection to which are connected щупы the voltmeter, testifies to resistance existence in connection.

PERFORMANCE ORDER
1. Connect "positive" щуп the voltmeter to a wire connected to the negative plug of the storage battery.
2. Connect "negative" щуп the voltmeter to the negative plug of the storage battery.
3. Include ignition and watch voltmeter indications. If the voltmeter shows tension existence, means, there is no reliable contact between a wire and the plug of the storage battery.
4. Connect "positive" щуп the voltmeter to a wire connected to the positive plug of the storage battery.
5. Connect "negative" щуп the voltmeter to the positive plug of the storage battery.
6. Include ignition and watch voltmeter indications. If the voltmeter shows tension existence, means, there is no reliable contact between a wire and the plug of the storage battery.
7. Connect the voltmeter for power failure measurement between the positive plug of the storage battery and contact of the traction relay to which the wire from the storage battery is connected.
8. Include ignition and a starter and watch voltmeter indications. If tension exceeds 0,2 In, it is necessary to clear and draw in contacts of the socket and to repeat check. If tension still exceeds 0,2 In, it is necessary to replace a wire connecting the positive plug of the storage battery and the traction relay of a starter.
9. Connect the voltmeter for power failure measurement between the negative plug of the storage battery and the block of cylinders of the engine.
10. Include ignition and a starter and watch voltmeter indications. If tension exceeds 0,2 In, it is necessary to clear and reliably to tighten wire fastening to the block of cylinders. If tension still exceeds 0,2 In, it is necessary to replace a wire connecting the negative plug of the storage battery and the block of cylinders of the engine.
11. Connect "positive" щуп the voltmeter to the starter case. Connect "negative" щуп the voltmeter to the negative plug of the storage battery.
12. Include ignition and a starter and watch voltmeter indications. If tension exceeds 0,2 In, the starter means is unreliably fixed on the block of cylinders of the engine.