KIA RIO

since 2000 of release

Repair and car operation



Rio KIA
+ 1.1. Short acquaintance to the car
+ 2. Engines A3E, A5D
+ 3. Greasing system
+ 4. Cooling system
+ 5. Fuel system
+ 6. Ignition system
+ 7. Coupling
+ 8. Transmission
+ 9. Axes and power shafts
+ 10. Suspension bracket
+ 11. Wheels and tires
+ 12. Steering
+ 13. Brake system
+ 14. Body
- 15. Air central air
   15.1. Specifications
   15.2. Contour of central air of air
   15.3. Remarks at replacement of elements of central air of air
   15.4. Connection of elements of central air of air
   15.5. Precautionary measures
   15.6. Verification of operational characteristics
   15.7. Diagnostics air central air with use of manometers
   15.8. Check of a gap of coupling of the compressor of the conditioner
   15.9. Check of coupling of the compressor of the conditioner
   15.10. Oil for greasing of the compressor of the conditioner
   15.11. Check of level and an oil dolivka in the conditioner compressor
   15.12. Air filter of the evaporator
   15.13. Sensor of double pressure
   15.14. Conditioner compressor
   15.15. Condenser check
   15.16. Check of the fan of the condenser
   15.17. Receiver \dryer check
   15.18. Check of the thermostatic sensor (termistor)
   15.19. Check of the engine of the fan
   15.20. Check of the block of resistors of the engine of the fan
   15.21. The switch of supply of air in car salon
   15.22. Control panel air central air
+ 16. Electric equipment


15.1. Specifications

GENERAL INFORMATION

Conditioner

Element
Specification
Compressor type
10PA 15C
type of oil and volume, cm3
ND–OIL8, 120
Belt of a drive of the compressor of the conditioner type
4PK
diameter of a pulley, mm
125

Sensor of double pressure of S/W

high pressure, psi (kg/cm2)
455±28 (32,0±0,2)
low pressure, psi (kg/cm2)
28±2,8 (2,0±0,2)
Coolant type
R134a
weight, g
650±25

Fan and evaporator

Element
Specification
Fan rotation direction
clockwise
quantity of steps
1–4
switching of steps
resistors
Evaporator type
DRAWN CUP
turning on / switching off of the conditioner
OFF:1,0±0,3°C
ON: 2,0±0,5°C
maximum capacity of cooling, kcal/h
4100±10 %
Heater maximum capacity of heating, kcal/h
3900±10 %